Calculation of Gamma-Ray Response Matrix for 5-cm NE-213 Organic Liquid Scintillation Detector
The gamma-ray response matrix is reported for a 5-cm NE-214 organic liquid scintallation detector. Gamma-ray response functions were determined by Monte-Carlo calculations of the pulse-height spectra. The calculational method was thoroughly tested by comparisons with measured results from several laboratory gamma-ray sources. The response matrix generated from these calculations is 186 x 93, covering a pulse-height range from 0.10 to 9.40 light units and an energy range from 0.22 to 11.99 MeV. The response matrix was tested by unfolding a variety of measured gamma-ray spectra. The detector efficiency is also presented. (Author).
- ISBN 10 : OCLC:227412654
- Judul : Calculation of Gamma-Ray Response Matrix for 5-cm NE-213 Organic Liquid Scintillation Detector
- Pengarang : N. A. Lurie, L Harris (Jr), J. C. Young, INTELCOM RAD TECH SAN DIEGO CALIF., L Harris (Jr), J. C. Young, INTELCOM RAD TECH SAN DIEGO CALIF., L Harris (Jr), J. C. Young, INTELCOM RAD TECH SAN DIEGO CALIF.,
- Bahasa : en
- Tahun : 1975
- Halaman : 151
- Halaman : 151
- Google Book : http://books.google.co.id/books?id=g5HotgAACAAJ&dq=intitle:5+cm&hl=&source=gbs_api
-
Ketersediaan :